Home | فارسی | Contact us | Subscribe to newsletter

March 29 2024  |  10 فروردين 1403

Your Source for Latest Advances in Iranian HVAC Industry

CEILING MODELS  

SARAVEL Fan coil units are intended for individually Controlled room air conditioning in buildings. Fan coils are used in hotels, office buildings and residential complexes, whereby a central plant supplies chilled and hot water for cooling and heating.

 

 

GENERAL NOMINAL COOLING AND HEATING CAPACITY

Model

Air flow

rate

(CFM)

Water flow

(gpm)

Cooling Cap.

(Btu/hr)

Heating

Cap.

(Btu/hr)

Cooling

Heating

Total

Sensible

SF-02

200

1.6

2.1

7800

5300

20100

SF-03

300

2.5

3.1

12400

8300

30300

SF-04

400

3.2

4.1

16100

10800

39500

SF-06

600

4.4

5.8

21900

15000

56000

SF-08

800

6.0

7.7

30000

20300

74700

SF-10

1000

7.5

9.6

37500

25300

93500

SF-12

1200

9.5

11.8

47400

31600

114600

 

GENERAL PHYSICAL DATA

Unit Size

SF-02

SF-03

SF-04

SF-06

SF-08

SF-10

SF-12

Face Area(sq.ft.)

0.9

1.4

1.6

1.9

2.4

3.1

3.8

Number Of Fans

1

2

2

2

3

4

4

Number Of Motors

1

1

1

1

2

2

2

Nominal Motors HP

1/30

1/25

1/20

1/20

1/20

1/20

1/20

Total Name Plate-Amps

0.2

0.24

0.24

0.3

0.5

0.6

0.6

High

Medium

Low

Approximate RPM

1000

700

1000

700

1000

700

1000

700

1000

700

1000

700

1000

700

 Note: Motor electrical characteristics are 220 V, 1 PH , 50 Cycles.

  

CEILING MODELS ARE HORIZONTAL UNITS,

AVAILABLE AS EXPOSED OR CONCEALED TYPES

 

Horizontal Model

Model HE


The model HE horizontal exposed unit is designed to be suspended from ceilings in new or existing buildings. All the components with the exception of the drain pan are the same as in the model TE. The model HE is furnished with an easily removable bottom panel which provides ready access to all the components for maintenance and service purposes.

 Horizontal Concealed Model

Model HC


The model HC horizontal concealed unit comes with a finished bottom access panel extending beyond the two side panels. The supply air outlet located in front of the unit provides a connection for ductwork which can supply the conditioned air to any number of diffuser configurations.

 

 

 

 

DIMENSIONS

Models

Wight (Kg)

Dimensions

LENGTH

WIDTH

HEIGHT

HE

HC

HE

HC

HE

HC

HE

HC

200

30

20

920

650

600

600

210

190

300

40

30

1120

850

600

600

210

190

400

40

30

1220

950

600

600

210

190

600

50

40

1360

1090

600

600

210

190

800

60

50

1620

1350

600

600

210

190

1000

70

60

1920

1650

600

600

210

190

1200

80

--

2270

2000

600

600

210

190

               Note: All dimensions are in mm.