Home | فارسی | Contact us | Subscribe to newsletter

March 29 2024  |  10 فروردين 1403

Your Source for Latest Advances in Iranian HVAC Industry

TOP DISCHARGE EXPOSED

FLOOR MODELS

SARAVEL Fan coil units are intended for individually Controlled room air conditioning in buildings. Fan coils are used in hotels, office buildings and residential complexes, whereby a central plant supplies chilled and hot water for cooling and heating.

 

 

GENERAL NOMINAL COOLING AND HEATING CAPACITY

Model

Air flow

rate

(CFM)

Water flow

(gpm)

Cooling Cap.

(Btu/hr)

Heating

Cap.

(Btu/hr)

Cooling

Heating

Total

Sensible

SF-02

200

1.6

2.1

7800

5300

20100

SF-03

300

2.5

3.1

12400

8300

30300

SF-04

400

3.2

4.1

16100

10800

39500

SF-06

600

4.4

5.8

21900

15000

56000

SF-08

800

6.0

7.7

30000

20300

74700

SF-10

1000

7.5

9.6

37500

25300

93500

SF-12

1200

9.5

11.8

47400

31600

114600

 

 

GENERAL PHYSICAL DATA

Unit Size

SF-02

SF-03

SF-04

SF-06

SF-08

SF-10

SF-12

Face Area(sq.ft.)

0.9

1.4

1.6

1.9

2.4

3.1

3.8

Number Of Fans

1

2

2

2

3

4

4

Number Of Motors

1

1

1

1

2

2

2

Nominal Motors HP

1/30

1/25

1/20

1/20

1/20

1/20

1/20

Total Name Plate-Amps

0.2

0.24

0.24

0.3

0.5

0.6

0.6

              High

Medium

Low

Approximate RPM

1000

700

1000

700

1000

700

1000

700

1000

700

1000

700

1000

700

 

Note: Motor electrical characteristics are 220 V, 1 PH , 50 Cycles.

 

 Model TE

 

The model TE is an exposed floor unit which is furnished in attractive decorative colors to match all interior decors. The one piece front panel is readily removable, allowing fast and complete access to the coil, fans, motor, speed control switch, electrical wiring, and fresh air damper. The fan deck slides out easily for maintenance. The filter can be removed and washed without having to remove the front panel.

 

Model SE

 

This model has an inclined top cabinet, designed for applications in schools, institutions, hospitals and public buildings, where books and other objects are likely to be placed over the discharge grilles of a flat-top design. The slanted design precludes this possibility.

 

Model TB .

 

The model TB "Lo-Boy" is a low silhouette top discharge exposed unit. The components and front panel arrangements are the same as the model TE.

The basic unit and all features are the same as those of the exposed model TE.

 

 

DIMENSIONS

Models

Wight (Kg)

Dimensions

LENGTH

WIDTH

HEIGHT

TE

SE

TE

SE

TB

TE

SE

TB

TE

SE

TB

200

30

30

920

920

920

210

210

300

600

660

340

300

40

40

1120

1120

1120

210

210

300

600

660

340

400

40

40

1220

1220

1220

210

210

300

600

660

340

600

50

50

1360

1360

1360

210

210

300

600

660

340

800

60

60

1620

1620

1620

210

210

300

600

660

340

1000

70

70

1920

1920

1920

210

210

300

600

660

340

1200

80

80

2270

2270

2270

210

210

300

600

660

340

Note: All dimensions are in mm.