| Custom
Built Air
Cooled Heat Exchanger |
|
 |
Pictured on the left is a custom-built air cooled heat exchanger for onshore
oil drilling platform applications. The unit was designed and
built to ASME
and API standards. The operating conditions
are as follows:
- Gas:
Compressed Natural Gas
- Gas Flow rate: 22400 lbs/hr
- Maximum
Design Pressure: 690 Psig
- Inlet
Gas Temperature = 320°F
- Outlet
Gas Temperature = 130°F
Contact
Saravel Corp.
Sales Office for specific gas cooling applications. |
|
| Non-Sparking
Centrifugal Fan |
|
Pictured
on the right is a
custom built-SWSI centrifugal fan equipped with non-sparking electric
motor.
The unit casing is constructed entirely of brass for corrosive
applications.
The fan size is 9" and
designed to deliver 1050 CFM at 1.25" w.g. static pressure. Contact Saravel Corp. Sales Office for specific
fan applications. |

|
|
|
| Hot
Air Furnace Units |
|
| Pictured
below is hot air furnace units equipped with Weishaupt dual fuel
burners delivered to IRAN KHODRO DIESEL, the leading bus manufacturer in Iran. |
|

Completed
unit prior delivery to the site |

Inside of the unit
|
|
| Read